1.
The Inogen One G5 comes with a 3-year warranty covering the concentrator and a 1-year warranty that covers the accessories.
5.
2. Attach the desired sized single or double batteryand zip up the bottom flap. The use ofnon-specified columns may create a safety hazard and/or impair equipment performance and will voidyour warranty.
When operating the Inogen One. Recharging time is up to 4 hours for asingle battery and 8 hours for a double battery. During oxygen therapy, a green LED will indicate that a breath has been detected and oxygen delivered. Do not wrap cords around power supply for storage.
If no breath is detected after 60 seconds, the concentrator enters an auto-pulse mode, which delivers regular intervals of metered oxygen until the next breath is detected. delivery when using a particular cannula, consult your physician.
Your nasal cannula should be replaced on a regular basis. WithinEurope, contact the EU Authorized Representative for disposal instructions.
Troubleshooting for these alerts can be found in the user manual.
At only 38 decibels, the G5 produces less noise than a normal indoor conversation which makes it ideal in quiet environments when you want to be unobtrusive.
To replace the fuse, follow these instructions and refer to the photograph below. The output filter is intended to protect the user from inhalation of small particles in the productgas flow. No Insurance Medical Supplies.
For the best experience on our site, be sure to turn on Javascript in your browser. It is the responsibility of the patient to make back-up arrangements for alternativeoxygen supply when traveling; Inogen assumes no liability for persons choosing not to adhere tomanufacturer recommendations.
Install a replacement fuse, Inogen RP#125 (BUSS MDA -12) and reassemble the tip. Nasal cannulas and tubing should also be replaced on a regular basis.
The battery will power the Inogen One G5 without connection to an external power source. Leaving your Inogen One G5 plugged in past the full charge time will not harmthe concentrator or the battery.
Use of a single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen delivery. Make certain that the nasal cannulais properly aligned on your face and you are breathing through your nose. FAA regulations require that all extra batteries to be individually wrapped and protectedto prevent short circuits and carried in carry-on baggage onboard aircraft only.
Inogen One G5 vs Inogen One G4 Comparison.
Non-returnable items include but are not limited to: Converts from a rollator to a transport chair. Batteries should not be left dormant for more than 90 days at a time.
You caneven takethe Inogen G5oxygen concentratorona plane to visit family or take avacationsince itmeets FAA requirements. When the concentrator detects that the battery life is low, with less than 10 minutes remaining, alow priority alert will sound.
This portable oxygen concentrator comes with both AC and DC power cords, allowing users the freedom to plug in anywhere. A change in altitude (for example, from sea level to mountains) may affect total oxygenavailable to the patient.
Additional monitoring or attention may be required for patients using this device who areunable to hear or see alerts or communicate discomfort. To extend the run-time of your battery, avoid running in temperatures less than 41F (5C) orhigher than 95F (35C) for extended periods of time.
Due toaircraft power limitations, the AC Power Supply cannot be used to charge the Inogen One G5 Batterywhen used on an aircraft.
It cannot be connected to a CPAP machine. For events other than those describedin this manual, contact your equipment provider for servicing by authorized personnel.
When powering the Inogen One G5 in an automobile ensure the vehicles. The following notification icons are accompanied by a single, short beep.
Power supply with attached power output cable to connect to the Inogen One G5. Pressing this button will change the volume level, from 1 to 4. Ensure that the automobile power socket is adequately fused for the Inogen One G5 powerrequirements (minimum 15 Amp).
The device produces enriched oxygen gas, which accelerates combustion.
To completelyremove power from the external battery charger, remove the plug. Do Not Power on the Inogen One G5 concentrator. Press the power button to turn on the Inogen One G5, and use normally. Press and hold the plus (+) and (-) minus button for 5 seconds. To turn this feature on or off, simply press the bell icon on the devices control panel.
The following steps can be done by pressing specific buttons on the devices screen or within Inogen Connect App.
Connect the AC power supply cord to the Inogen One G5 and plug the power supply AC cord into an electrical outlet.
To purchase additional particle filters contact your equipment provider or Inogen. The Inogen One G5 will alert with audible and visual signals for no breath detected when this mode is enabled and no breath has been detected for 60 seconds.At 60 seconds, the device will enter into auto pulse mode and once another breath is detected, the device will exit auto pulse mode and deliver normally on inspiration. The Inogen One G6 is one solution for oxygen at home, away, and for travel, 24/7.
Make sure the Inogen One G5 is in a location where the alerts can be heard or will be recognizedif they occur. The starter package comes with the Inogen G5 unit, single battery, AC power supply, DC power cable, carrying bag, and manual.
The Inogen One G5 will sense the onset of inhalation and deliver a burst of oxygen at a precise time when you inhale.The Inogen One G5 will sense each breath and continue to deliver oxygen in this manner.
The Inogen One G5 will normally sensethe next breath and deliver oxygen accordingly.
Hygienic items including all bath safety equipment, bed pads, and personal care items, Respiratory supplies including tubing, masks, cannulas, filters, etc, Special order, customized items, and online-only products. 11 Brick Ct
Insert the Inogen One G5 into the carry bag through the bottom zippered opening with thecannula barb facing up on the right front side. A caution indicates that a precaution or service procedure must be followed.
The use of non-specified power supplies, power cables or accessories may create asafety hazard and/or impair equipment performance. Unique to this device is a pair of columns (sieve beds) that require replacement every 12-18 months. Subscribe to our free newsletter and receive a 10% off coupon to use on your first purchase.
Use of this device with a humidifier,nebulizer or connected with any other equipment may impair performance and/or damage the equipment.Do not modify the Inogen One G5 Concentrator.
Do not remove the tamper evident label.
If you need additional support, dont hesitate to contact our customer care team.
Disregardinga caution could lead to a minor injury or damage to equipment. When battery life is low, do one of the following: Plug the Inogen One G5 into an AC or DC power source using the AC power supply or DCcable. Under certain circumstances, the use of non-prescribed oxygen therapy can be hazardous.This device should be used only when prescribed by a physician.
A single short beep will sound after the Inogen logo is displayed.
If an extension cord must be used,use an extension cord that has an Underwriters Laboratory (UL) Mark and a minimum wire thickness of18 gauge.
Bellevue Healthcare has limited inventory of Inogen Portable Concentrators and Batteries due to shipping delays.
+ Include: battery (1), AC power supply, DC power cable, carrying bag, and manual. Similar to other portable oxygen concentrators, the Inogen One G5 can provide oxygen delivery in six different pulse dose settings. The display will indicate the selected flow setting and power condition.
Ensure the power supply is in a well ventilated location as it relies on air circulationfor heat dissipation. Connection of the Inogen One G5 to an IT-Network could result in previously unidentifiedrisks to patients, operators or third parties.
The Inogen One G5 can be operated using battery power during transport withthe Carry Bag.
Note: IT-network is a system composed of wireless (Bluetooth) transmission between the Inogen OneG5 and the Inogen Connect Application.
The G5 portable oxygen concentrator must be maintained regularly in order to receive effective and efficient therapy. Alternative/optional way of carrying your Inogen One G5, hands free, more comfort, out of your way with extra pockets for additional accessories.
As with all of our portable oxygen concentrators, the Inogen One G5 is FAA-approved for in-flight use.
A yellow light indicates either a change in operating status or a condition that may need response (alert). The extra cannula tubing can be tucked into the open pocket on the front flap of the bag.
Operating thedevice without the engine running may drain the vehicles battery.
Clean the particle filters with a mild liquid detergent.
For optimal sieve bed(columns) life, the product should be used frequently.
The userof the Concentrator should make sure it is used in such an environment. For assistance, if needed, in setting up, using, maintaining, or to report unexpected operation orevents, contact your equipment provider or manufacturer.
A warning indicates that the personal safety of the patient may be involved. If you are using Inogen Connect App, navigate to the Advanced screen, then to AdditionalInformation screen and click on the Column Reset button. The air intake filter, located on the side of the unit, should be removed and washed with warm water and mild detergent weekly.
Do not use the power supply with a cigarette plug splitter or with an extension cable.This may cause overheating of the DC power input cable.
For the best experience on our site, be sure to turn on Javascript in your browser.
Be sure to contact your airline for their specific requirements for traveling with an oxygen device.
The lightning bolt indicates that an external power supply is connected. This device is NOT INTENDED to be life sustaining or life supporting. The battery must not be incinerated.
engine is running first before connecting DC cable into cigarette lighter adapter.
G5 from an AC or DC external power supply, a properly inserted Inogen One G5 battery should bemaintained in the unit. Never leave the Inogen One G5 in an environment which can reach high temperatures, suchas an unoccupied car in high temperature environments. Inogen One G5 Portable Oxygen Concentrator, 7.19 inches Wide x 3.26 inches Deep x 8.15 inches High (includes single battery), Intelligent Delivery Technology: Six flow settings from 1-6, 38 decibels at a 3.0 pulse dose setting (Quiet conversation), Temperature: 41 104 Fahrenheit (5 40 Celsius), AC Power Supply 100-240V, 50-60Hz (auto sensing to allow worldwide use), Temperature: -13 158 Fahrenheit (-25 70 Celsius), Simple control functions and easy-to-read LCD display, Yes Can connect with Inogen Connect Mobile App, + One solution for oxygen at home, away, and for travel, + Quiet: low decibels allow for discrete use even in quiet settings.
If you begin to feel ill or are experiencing discomfort while using this device, consultyour physician immediately. This portable oxygen device includes several built-in alarms and alerts to let users know when it is not functioning properly. If the DC input cable is being used with aknown good power source and the unit is not receiving power, the fuse may need to be replaced.
The AC power supply provides the precise current and voltage required tosafely power the Inogen One G5 and is designed to operate from specified AC power sources. The carry strap has a removable shoulder pad and has an adjustable strap from 24 to 48 in length. A nasal cannula must be used with the Inogen One G5 to provide oxygen from the concentrator. If the Inogen One G5 is being powered by the AC power supply or DC power, batteries will chargeduring operation.
The Inogen One G5 Concentrator is designed for continuous use. (such as DawnTM) and water; rinse in water and dry before reuse.
Subsequent changes to the IT-network could introduce new risks and require additionalanalysis. Do not use theInogen One G5 in presence of flammable anesthetics, cleaning agents or other chemical vapors.
Use the or + flow setting control buttons to select the setting as shown on the display.
The screen will display thefollowing informational icon. There is one additional feature for attaching the bag to a luggage or cart handle for ease of not having to carry the bag while also pulling luggage or a cart.
To ensure that your battery is properly charging, inspect that the correct AC and. Store with a charge of 40-50%. The tip of the Cigarette Adapter Plug becomes HOT when in use. Do not allow smoking or open flames of this device while in use.
The Cigarette Lighter DC power plug contains a fuse.
document.getElementById("copyright_year").innerHTML = new Date().getFullYear(); Product Features:
Make sure the power supplycools down before handling. 1.
2. 3. Note that failure to respond to the cause of an alert condition for low, medium and high priorityalerts potentially will result in discomfort or reversible minor injury only and develop within aperiod of time sufficient to switch to a backup source of oxygen.
7. The Inogen One G5 external battery charger will charge the Inogen One G5 single and double batteries. Additional warm up time may be needed if your Inogen One G5 has been stored in extremely cold temperatures.
8. To ensure oxygen flow, ensure that the nasal cannula is properly connected to the nozzlefitting and that the tubing is not kinked or pinched in any way.
The AC power supply is used with the following components: 1.
A green light will flash each time a breath is detected.
Avoid use of the Inogen One G5 in presence of pollutants, smoke or fumes. 4. If multiple alert conditions are detected, the highest priority alert will be displayed. NOTE: The AC Power Supply cannot be used to charge the Inogen One G5 battery when onboard aircraft.Traveling by bus, train or boat, contact your carrier to find out about power port ability.
Mathematical algorithms and time delays areused to reduce the probability of false alerts while still ensuring proper notification of an alertcondition.
The Inogen One G5 is not designed or specified to be used in conjunction with ahumidifier, nebulizer or connected with any other equipment.
Replacement intake particle filters RP-500.
The power supply may become hot during operation. If the power socket cannot support a 15 Amp load, the fuse may blow or the socket may be damaged.
More frequent beeps indicate higher priority conditions. 1.
Welcome to No Insurance Medical Supplies!
Follow the step-by-step instructions in the user manual to properly replace these components.
The particle filters must be cleaned weekly to ensure the ease of air flow.
5.
Ensure particle filters are in place at both ends of device.
Position the nasal cannula on your face and breathe through your nose. Set the Inogen One G5 Concentrator to the flow rate prescribed by your physician orclinician.
RTCA DO 160. Pressing this button will toggle the Inogen One G5s breath detection audible alert on and off.Breath Detection Alert Mode.
Turn on your Inogen One G5 by pressing the ON/OFF Button. When the single or double battery is not attached to the Inogen One G5 Concentrator, you can checkthe battery gauge on the battery to determine the amount of charge available.
This could leadto electrical shock and/or damage.
The DC power input cable connects directly to the automobile cigarette lighter or auxiliary DC power supply. You must check with yourairlines.
The Inogen One G5 monitors various parameters during operation and utilizes an intelligent alertsystem to indicate a malfunction of the concentrator.
Examples of some of these alerts include: no breath detected, battery low, operating temperature high/low, and system failure.
Determine the amountof battery charge available by pressing the green battery icon button and observing how many LEDsilluminate. Connect the AC power plug to the power source and connect the power output plug to the Inogen One G5. The default volume is set at level 1 and can be adjusted to higher settings but it can not be silenced.
Operation is subject to the following twoconditions: (1) this device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation.
Changes in the IT-network configuration; Connection of additional items to the IT-network, Disconnecting items from the IT-network, Updating equipment connected to the IT-network.
If alert persists, contact yourequipment provider. Do not use oil, grease, or petroleum- based products on or near the Inogen One G5.
The displays mode indication area will show a bell icon, flashing yellow light and display message when the alert is enabled.If power is lost, the breath detection audible alert remains set in the user preferred mode. The metal column assembly can be seen on one side of the device. To avoid danger of choking or strangulation hazard, keep cords away from children andpets. NOTE: These contacts are not powered unless a battery is in place and charging. It can be charged at home or on the go giving you the freedom you deserve. If the battery is drained, charge the battery or remove it from the concentrator.
Disregardinga warning could result in injury.
Additional titration may be needed to ensure proper oxygen. Blockage of aircirculation or proximity to a heat source may lead to internal heat buildup and shutdown or damage to the concentrator. NOTE: When starting to charge a fully discharged battery, the charging process may start and stopduring the first few minutes.
This mode alerts users with both visual and audible signals when no breath is detected for more than 60 seconds.
Air intake and exhaust must have clear access. The battery containslithium ion cells and should be recycled.
Large, intuitive controls and a bright, backlit display are just the beginning of what this machine has to offer. Inogen One G5 Single Battery For Inogen One G5, Inogen One G5 External Battery Charger with Power Supply, Rechargeable Battery (Option to be selected at Check-out). Connect the nasal cannula tubing to the nozzle fitting.
3.
Following a brief start-up sequence, a warm up period up to 2 minutes will initiate. This procedure will ensure uninterrupted operation and will operate allalerts and alerts in the event of a loss of the external power supply. Do not jump start the automobile with the DC power cable connected. Note: Additional options may be available for country-specific power cords.
The Inogen One G5 includes an output filter conveniently located behind the removablecannula nozzle fitting.
Place the Inogen One G5 in a well ventilated location.
FAA Approved for usage during flights, cruise ships and other forms of transportation.